Asenware Manual Call Point
Asenware Manual Call Point is designed to be used with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points. When the manual fire call points are operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit.
1 Semi-flush or surface mounting
2 Compatible with the latest EN standards
3 Lever reusable (non-glass break)
4 LED indicator
KSh1,000.00Asenware Manual Call Point
KSh1,000.00 -
Asenware Fire Alarm Smoke Detector
Asenware Fire Alarm Smoke Detector Suitable place for smoke Detector.
Where is the smoke detector, one of the fire fighting equipment, suitable for installation? Many people don’t know. Here is a brief introduction to the places where smoke detectors are applicable:
Halls, bedrooms, offices, etc. of restaurants, hotels, teaching buildings, and office buildings;
Electronic computer room, communication room, movie or TV projection room, etc.;
Stairs, walkways, elevator machine rooms, etc.;
Book stacks, archives, etc.;
Places with electrical fire hazards.KSh1,200.00Asenware Fire Alarm Smoke Detector
KSh1,200.00 -
Asenware Battery Powered Smoke Detector
Asenware Battery Powered Smoke Detector is a photo-detector that uses the most advanced optical sensing chamber. It is designed to provide open area protection without wiring, and it is easy to install and construct.
Asenware Battery Powered Smoke Detector specifications:-
Operating Voltage:- 9VDC(with battery)
Operating Current:- Monitoring Status <= 8uA, alarm status<= 20mA Temprature:- -10 Degree Celcius ~ 55 Degree celcius Relative humidity:- <= 95% non condensing Protection class: IP20 Application: Indoor use only Smoke Alarm Sensitivity:- 0.18 to 0.26 dBM Alarm level: >= 85dB@3m and >= 93dB@1m
Materials and colors:- ABS, whiteKSh1,400.00Asenware Battery Powered Smoke Detector
KSh1,400.00 -
Strobe Sounder For Conventional Fire Alarm System
Fire Strobe Sounder is a kind of terminal device for alarm; it is used for the sound and light alarm when the fire happens.
Fire Strobe Sounder feature
Adopt the two-wire or the four-wire system wiring method.
The main line end receives two main lines, No polarization.
Connect the power end to DC24V power line.KSh1,700.00 -
Fire Alarm Sounder and Strobe Light
Fire Alarm Sounder and Strobe Light is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.
1. Adopt the two-wire or the four-wire system wiring method
2. The mainline end receives two main lines, No polarization
3. Connect the power end to a DC24V power line.
Conventional Fire Alarm Sounder and Strobe Technical parameters:
operating voltage: dc20v~28v
working current: 100ma~150ma
flash intensity: ≥1.2ws flash period: ≤1.5s
temperature range: -10oc ~ +50oc
humidity range: 0%~95%rh
sound pressure level: ≥100db
life of flashlight: ≥40000KSh1,700.00Fire Alarm Sounder and Strobe Light
KSh1,700.00 -
Two Core Fire Alarm Cable 1.5mm 100m
Two Core Fire Alarm Cable 1.5mm is designed to resist the spread of fire into a new area. Fire-resistant or fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.
We supply and install fire-rated alarm cable, which conforms to (UL) 758 and ISO 9001 Standard.
Two core, 100m per roll.KSh5,800.00Two Core Fire Alarm Cable 1.5mm 100m
KSh5,800.00 -
16AWG Asenware Pure Fire Alarm Resistant Cable
16AWG Asenware Fire Alarm Resistant Cable has been specially designed and thoroughly tested to retain its durability and reliability when fire strikes.
A fire alarm system is reliant in no small part to the cabling that connects the devices and supplies power. Without reliable, robust cable the fire alarm system would be prone to costly faults and malfunctions. It is therefore essential that you only use the best cable, fitted by qualified electricians, in your fire alarm system.
16AWG Asenware Fire Alarm Resistant Cable Specifications:-
Type : Insulated
Conductor Type: Solid
Application: Heating
Conductor Material: Copper
Sheath Material: PVC
KSh9,500.0016AWG Asenware Pure Fire Alarm Resistant Cable
KSh9,500.00 -
2 Zone Asenware Conventional Fire Alarm Panel
2 Zone Asenware Conventional Fire Panel Features:-
Item – 2 Zone Panel
Model No. – AW-CFP2166-2
Mains Supply Voltage – 110VAC or 240VAC
Internal Power Supply – 27.2VDC
Total Output Current – 500mA @ 240VAC
Batteries (Default Conf) – 12V 2AH * 2 = 24VDC in Total
End of Line Device – 6.8kOhms. 5% tolerance, 0.25W (color code – blue,grey,red,gold)
Dimensions(mm) – 320*231*90mm
Weight – 5KG
Weight(with batteries) – 6.8KG
KSh13,500.002 Zone Asenware Conventional Fire Alarm Panel
KSh13,500.00 -
4 Zone Asenware Conventional Fire Alarm Panel
4 Zone Asenware Conventional Fire Panel Features:-
Item – 4 Zone Panel
Model No. – AW-CFP2166-4
Mains Supply Voltage – 110VAC or 240VAC
Internal Power Supply – 27.2VDC
Total Output Current – 3A @ 240VAC
Batteries (Default Conf) – 12V 2AH * 2 = 24VDC in Total
End of Line Device – 6.8kOhms. 5% tolerance, 0.25W (color code – blue,grey,red,gold)
Dimensions(mm) – 395*502*124mm
Weight – 7KG
Weight(with batteries) – 9.6KG
KSh16,500.004 Zone Asenware Conventional Fire Alarm Panel
KSh16,500.00 -
8 Zone Asenware Fire Alarm Control Panel
8 Zone Asenware Fire alarm control panel Specification:-
It is modularized design, the panel can expend from 1 zone to 32 zones easily.
It has 2 level control mode by a lock
It has 24VDC and 5VDC power supply output.
It has FIRE and FAULT signal output.
It has 2 general sounders output.
Each zone has 1 circuit detectors input .
Each zone can be disable by a button.
It has RESET button to reset the panel.
It has SILENCE button to stop BUZZER and SOUNDERS.
It has EVACUATE button to start a manual fire alarm immediately.
It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
It has an optional GSM module for fire alarm by SMS .KSh22,000.008 Zone Asenware Fire Alarm Control Panel
KSh22,000.00