• Asenware Manual Call Point

    Asenware Manual Call Point is designed to be used with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points. When the manual fire call points are operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit.

    1 Semi-flush or surface mounting

    2 Compatible with the latest EN standards

    3 Lever reusable (non-glass break)

    4 LED indicator

  • Asenware Fire Alarm Smoke Detector

    Asenware Fire Alarm Smoke Detector Suitable place for smoke Detector.

    Where is the smoke detector, one of the fire fighting equipment, suitable for installation? Many people don’t know. Here is a brief introduction to the places where smoke detectors are applicable:
    Halls, bedrooms, offices, etc. of restaurants, hotels, teaching buildings, and office buildings;
    Electronic computer room, communication room, movie or TV projection room, etc.;
    Stairs, walkways, elevator machine rooms, etc.;
    Book stacks, archives, etc.;
    Places with electrical fire hazards.

  • Asenware Battery Powered Smoke Detector

    Asenware Battery Powered Smoke Detector is a photo-detector that uses the most advanced optical sensing chamber. It is designed to provide open area protection without wiring, and it is easy to install and construct.

    Asenware Battery Powered Smoke Detector specifications:-
    Operating Voltage:- 9VDC(with battery)
    Operating Current:- Monitoring Status <= 8uA, alarm status<= 20mA Temprature:- -10 Degree Celcius ~ 55 Degree celcius Relative humidity:- <= 95% non condensing Protection class: IP20 Application: Indoor use only Smoke Alarm Sensitivity:- 0.18 to 0.26 dBM Alarm level: >= 85dB@3m and >= 93dB@1m
    Materials and colors:- ABS, white

  • Strobe Sounder For Conventional Fire Alarm System

    Fire Strobe Sounder is a kind of terminal device for alarm; it is used for the sound and light alarm when the fire happens.

    Fire Strobe Sounder feature
    Adopt the two-wire or the four-wire system wiring method.
    The main line end receives two main lines, No polarization.
    Connect the power end to DC24V power line.

  • Fire Alarm Sounder and Strobe Light

    Fire Alarm Sounder and Strobe Light is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.

    1. Adopt the two-wire or the four-wire system wiring method

    2. The mainline end receives two main lines, No polarization

    3. Connect the power end to a DC24V power line.
    Conventional Fire Alarm Sounder and Strobe Technical parameters:
    operating voltage: dc20v~28v
    working current: 100ma~150ma
    flash intensity: ≥1.2ws flash period: ≤1.5s
    temperature range: -10oc ~ +50oc
    humidity range: 0%~95%rh
    sound pressure level: ≥100db
    life of flashlight: ≥40000

  • Two Core Fire Alarm Cable 1.5mm 100m

    Two Core Fire Alarm Cable 1.5mm is designed to resist the spread of fire into a new area. Fire-resistant or fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.

    We supply and install fire-rated alarm cable, which conforms to (UL) 758 and ISO 9001 Standard.
    Two core, 100m per roll.

  • 16AWG Asenware Pure Fire Alarm Resistant Cable

    16AWG Asenware Fire Alarm Resistant Cable has been specially designed and thoroughly tested to retain its durability and reliability when fire strikes.

    A fire alarm system is reliant in no small part to the cabling that connects the devices and supplies power. Without reliable, robust cable the fire alarm system would be prone to costly faults and malfunctions. It is therefore essential that you only use the best cable, fitted by qualified electricians, in your fire alarm system.

    16AWG Asenware Fire Alarm Resistant Cable Specifications:-

    Type : Insulated

    Conductor Type: Solid

    Application: Heating

    Conductor Material: Copper

    Sheath Material: PVC

  • 2 Zone Asenware Conventional Fire Alarm Panel

    2 Zone Asenware Conventional Fire Panel Features:-

    Item – 2 Zone Panel

    Model No. – AW-CFP2166-2

    Mains Supply Voltage – 110VAC or 240VAC

    Internal Power Supply – 27.2VDC

    Total Output Current – 500mA @ 240VAC

    Batteries (Default Conf) – 12V 2AH * 2 = 24VDC in Total

    End of Line Device – 6.8kOhms. 5% tolerance, 0.25W (color code – blue,grey,red,gold)

    Dimensions(mm) – 320*231*90mm

    Weight – 5KG

    Weight(with batteries) – 6.8KG

  • 4 Zone Asenware Conventional Fire Alarm Panel

    4 Zone Asenware Conventional Fire Panel Features:-

    Item – 4 Zone Panel

    Model No. – AW-CFP2166-4

    Mains Supply Voltage – 110VAC or 240VAC

    Internal Power Supply – 27.2VDC

    Total Output Current – 3A @ 240VAC

    Batteries (Default Conf) – 12V 2AH * 2 = 24VDC in Total

    End of Line Device – 6.8kOhms. 5% tolerance, 0.25W (color code – blue,grey,red,gold)

    Dimensions(mm) – 395*502*124mm

    Weight – 7KG

    Weight(with batteries) – 9.6KG

  • 8 Zone Asenware Fire Alarm Control Panel

    8 Zone Asenware Fire alarm control panel Specification:-

    It is modularized design, the panel can expend from 1 zone to 32 zones easily.
    It has 2 level control mode by a lock
    It has 24VDC and 5VDC power supply output.
    It has FIRE and FAULT signal output.
    It has 2 general sounders output.
    Each zone has 1 circuit detectors input .
    Each zone can be disable by a button.
    It has RESET button to reset the panel.
    It has SILENCE button to stop BUZZER and SOUNDERS.
    It has EVACUATE button to start a manual fire alarm immediately.
    It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
    It has an optional GSM module for fire alarm by SMS .

Main Menu